Tagged With "4.4.2"

Topic

Problem to open ver 4.4.2 (HandShakeReq)

Björn Carlsson ·
Hi I cant open CSP files that were bulid in just 2 weeks ago. I have tried two different computers both on windows 10. If I do a new desing in 4.4.2 it works. If I do a new design i 5.1 I have the same problem. See attached picture. My windows 10 was auto updated 12 september after the design orginaly was built. What to do?
Reply

Re: Problem to open ver 4.4.2 (HandShakeReq)

Arno-at-Bose ·
Hello Bjorn, Sorry to read you experiencing this issue. Can you send me you design file and a screenshot of the Hardware Manager when the firmware tab is selected? Thanks in advance, BR Arno
Reply

Re: Problem to open ver 4.4.2 (HandShakeReq)

Arno-at-Bose ·
Hi Bjorn, To where or how did you sent it, as I haven't received anything yet? BR Arno
Reply

Re: Problem to open ver 4.4.2 (HandShakeReq)

Björn Carlsson ·
You got mail!
Reply

Re: Problem to open ver 4.4.2 (HandShakeReq)

Arno-at-Bose ·
Yes I received it. Thanks and I will have a look at it.
Reply

Re: Problem to open ver 4.4.2 (HandShakeReq)

Björn Carlsson ·
Got it now?
Reply

Re: Problem to open ver 4.4.2 (HandShakeReq)

Björn Carlsson ·
I have found the problem! I work at home. In my house I have one ESP1600 and one ESP1240. (Yes I know this is little odd ) This units are connected to my network that have connection to my wireless router and to my computer to surf. When I am connected to my router the problem occur! This happens even if I don't try to go online in CSD. This has never been a problem before. The last design I did was in 8 september and it went well. 12 september my computers auto updated windows 10. After...
Reply

Re: Problem to open ver 4.4.2 (HandShakeReq)

Arno-at-Bose ·
Great you found the problem. Thank you for your time and effort. Can you check to which version windows 10 is updated? WIN+R -> and type winver in the run dialog and press enter. Can you connect when you disable the wifi connection and connect via your "internet" connection? You can also try to change the "host network interface" from "automatic selection" to one of the NICs We always advise to have only one network connection to the Bose system. BR Arno
Reply

Re: Problem to open ver 4.4.2 (HandShakeReq)

Björn Carlsson ·
Windows 10 Home ver 1803 I have only the wireless connection, not cable = only one connection. You can also try to change the "host network interface" from "automatic selection" to one of the NICs. This is greek to me... please explain.
Reply

Re: CSD v5.3 & CSR builder v2.4

Berd ·
Hello gentlemen, I have email to you Arno, also checkout my video which i email you on the Jan 2. Have a nice day.
Topic

CSD v5.3 & CSR builder v2.4

Berd ·
Hello everyone, Happy New Year 2019! I have a client using iphone x, and on new year's eve he updated his iphone ios & all updates on the app store update, including CSR to v2.4.0 He power-on the system the next day & immediately he "lost" control of his CSR APP. Client did not have any CC16 to manage the psets. Prior to this case, he was happily using the old iphone 6s and everything was working fine. After iphone X & everything else updated, dang! After recovery, i loan the...
Reply

Re: CSD v5.3 & CSR builder v2.4

Arno-at-Bose ·
Hi Bernard / Guillaume, Happy New Year to you too. I just tested it with CSD 5.3.2.28381 (FW 2.800) iPad (12.1.1) CSRclient 2.4.0.28163 But not able to reproduce so far. @Berd , have you also tested it with an updated IPhone 6s? Can you send me the CSD and CSR file? Thank you in advance and sorry for the inconveniences. BR Arno @Chris Chua
Reply

Re: CSD v5.3 & CSR builder v2.4

Guillaume-at-Bose ·
Hello Bernard, Happy New Year to You also ! I had the case with one of my reseller too. Only the gain blocks were responding. No control for Parameter Sets. Devices are : 1x PM8500N + an I-PAD 9,7'' with the last iOS installed CSD is running version 5.3.2.28381 + CSR version 2.4 Best regards
Reply

Re: CSD v5.3 & CSR builder v2.4

Arno-at-Bose ·
Hi Bernard / Guillaume, I nailed it down to the Pset dropdown list. Pset buttons will work fine. I've logged this issue. Workaround is to use Pset buttons instead of the Pset dropdown list. If Pset dropdown list is needed, add a Pset button to your canvas. When CSRclient start to be unresponsive after power cycling the ESP, press one time on the Pset button. After that the Pset dropdown list will work again. Sorry for the inconveniences. BR Arno
Having trouble signing in?

We recently updated our sign-in procedure and if you have old sign-in data cached, this can create a problem. Please:

  1. Clear your browser cache and cookies
  2. Then close the browser (not just the window)
  3. Open the browser and try again
Thank you

Please make sure that your profile is up to date
×
×
×
×