Tagged With "EX1280C"

Topic

Ethernet Commands

steve-at-bose ·
Hi. A customer of mine has asked if there is a way to query an EX1280C for serial number and Mac address via ethernet. Thanks in advance for your help. Steve
Reply

Re: Ethernet Commands

steve-at-bose ·
Have found that the arp -a command will return the Mac address of all the devices on the network. Still looking for a solution for finding serial numbers. Thanks Steve
Reply

Re: Ethernet Commands

Arno-at-Bose ·
Hi Steve, Sorry for responding so late, but I'm verifying the possibilities. An overview of the MAC address can also be found in the Hardware Manager (System -> Hardware Manager (Network Settings). As far as I know we do not save the serial number in each device. Can you tell me what the reason is why you want to retrieve the MAC address and Serial Number via Ethernet? BR Arno
Reply

Re: EX1280C compatible with DALI protocol

Arno-at-Bose ·
Hi Ricardo, The Bose EX-1280C supports RS232 or SoIP control (see attached the serial protocol). I have no experiences with DALI, but found several DALI-RS232 interfaces on the internet. Perhaps you can try one of these (or contact the manufacturer). If you find a good working DALI-RS232 interface, we would appreciate if you can post this onto our forum, as it might be helpful for others also. If you need any other support, please let us know. Thanks in advance. BR Arno
Topic

EX1280C compatible with DALI protocol

Ricardo Barreiros ·
Hi, My name is Ricardo Barreiros from ABC/ Portugal, and i have a project with EX-1280C, where i need to integrate in protocol DALI. The end user have a solution in another place where he controls (AC, Light, and sound) with a tablet. They use protocol DALI to control everything in same App. Anyone can tell me if it's possible? Thanks, Ricardo Barreiros +351916620925
Reply

Re: EX1280C compatible with DALI protocol

Darryl@bose ·
Hi Ricardo, The EX-1280C is not compatible with DALI unfortunately. One option, if the customer wants to use the same app, is to have the app developer write some specific commands to control the EX-1280C. Our protocol is realatively simple if they just want to set some scenes and control volume. Best regards, Darryl